- The question
- Before designing a heat store, check how material assumptions and calculation resolution affect a predicted heating cycle.
- The work
- Model a 40 × 30 × 10 mm aluminium-silicon sample, compare calculation grids and repeat the calculation with shorter time steps.
- The result
- The selected 33-plane grid differs from the finer 65-plane grid by 1.4207 °C at the centre, below the declared 3 °C limit. The coarse 17-plane grid is rejected.
- What it does not prove
- This compares calculations, not measured alloy performance. The model excludes liquid flow, the container and imperfect thermal contact. The original screening record remains 219 of 220 checks passed.